Dd96S-B railway panel indicator

Summary
Rectangle panemeter for railway applications
Specifications
General specifications

Accuracy
1.5 % F.S.D. addirional 0.75 % / 10 °C

Operating temperature
-25 °C...+70 °C

Humidity
at 40 °C max. 95 %

Protection
IP54
rear IP50 (terminals IP00)

Vibrations
5...150 Hz, 2 g random 3 x 5 h acc. EN 61373 (50155)

Shock
acc. EN 61373

Test voltage
2 kV

Illumination
LEDS, any voltage between 24 and 110 VAC/VDC

Scale and pointer
Black scale, white pointer and figures

Terminals
Movement: M5, illumination: faston 6.3 x 0.8
Signal Leds: screw terminals
km counter : screw terminals

Glass
Low reflection

Panel mounting
With four screws

International Standards

IEC 571
EN 60051
EN 50155
EN 50121
EN 61373

Movement signal

0...20 mA
4...20 mA
0...2.5 mA
0...10 V
other inputs on request zero left or middleB : acc. EN50155 (standard)
W : white scale

Options

White scale with black pointer and printing

Pointers yellow, white or red

Brand label on scale

Red-line marking(s) on the scale

Coloured band(s) in the scale