| Old model |
Product |
New model |
Pin-to-pin compatible |
Main differences new model compared to old model |
Obsolescence date |
| FDA-U200 |
Flashing relay |
FDA4-U200N |
Yes |
4 C/O contacts instead of 2 C/O contacts, 23 mm higher |
July 1, 2023 |
| FDA-U300 |
Flashing relay |
FDA4-U200N |
Yes |
4 C/O contacts instead of 2 C/O contacts, 23 mm higher |
July 1, 2023 |
| KCS-U200 |
Latching relay |
Suggestion for replacement: BD-U200N series |
n.a. |
n.a. |
January 1, 2023 |
| RC-19A |
Current monitoring |
CMP relay |
n.a. |
n.a. |
January 1, 2023 |
| UB 001 |
Voltage monitoring relay |
No new model available |
n.a. |
n.a. |
June, 2022 |
| UB 002 |
Voltage monitoring relay |
No new model available |
n.a. |
n.a. |
June, 2022 |
| ACD-U200 |
Voltage monitoring relay |
MTDV4-U200 |
yes |
4 C/O contacts instead of 1 C/O + 1 N/O contact, time delay options |
February 1, 2017 |
| ACTD4-U200 |
Timer & voltage monitoring relay |
MTDV4-U200 |
yes |
Smaller footprint, delay-off possibility |
February 1, 2017 |
| NSR |
Overvoltage and undervoltage monitoring relay |
n.a. |
n.a. |
n.a. |
October 1, 2018 |
| PDF3-U200 |
1-shot relay |
CTD4-U200 |
yes |
Smaller footprint |
February 1, 2017 |
| TDBE-U200 |
Timer relay |
TDBE4-U200 |
no |
3 C/O + 1 N/C contact instead of 2 C/O contacts |
February 1, 2017 |
| TDE-U200 |
Timer relay |
TDE4N-U |
yes |
4 C/O contacts instead of 1 C/O contact + 1 N/O contact |
May 1, 2016 |
| TDE3-U200 |
Timer relay |
TDBE4-U200 |
no |
3 C/O + 1 N/C contact instead of 3 C/O contacts, delay-on possibility |
February 1, 2017 |
| TDE4-U200 |
Timer relay |
TDE4N-U |
yes |
Smaller footprint |
May 1, 2016 |
| UMD-U200 |
Voltage monitoring relay |
MTDV4-U200 |
yes |
4 C/O contacts instead of 1 C/O + 1 N/O contact, time delay options |
February 1, 2017 |
| V10 |
Relay socket |
V16 |
yes |
Integrated retaining clip, suitable for both wall and 35 mm rail mounting |
October 1, 2015 |
| V11 |
Relay socket |
V16-D |
yes |
Integrated retaining clip, suitable for both wall and 35 mm rail mounting |
October 1, 2015 |
| V12 |
Relay socket |
V16 |
yes |
Integrated retaining clip, suitable for both wall and 35 mm rail mounting |
October 1, 2015 |
| V13 |
Relay socket |
V16-D |
yes |
Integrated retaining clip, suitable for both wall and 35 mm rail mounting, if a LED is required use a CU-relay+LED |
October 1, 2015 |
| V14 |
Relay socket |
V18 |
yes |
Integrated retaining clip, use CU relay instead of CP relay |
October 1, 2015 |
| V15 |
Relay socket |
V16-D |
yes |
Integrated retaining clip, suitable for both wall and 35 mm rail mounting, if a LED is required use a CU-relay+LED |
October 1, 2015 |
| V24 |
Relay socket |
V23 or |
yes |
Suitable for both wall and 35 mm rail mounting, screw terminals instead of faston terminals |
March 1, 2014 |
| V29 |
Suitable for both wall and 35 mm rail mounting, spring clamp terminals instead of faston terminals |
| V25 |
Relay socket |
V23 or |
yes |
Suitable for both wall and 35 mm rail mounting, screw terminals instead of faston terminals |
March 1, 2014 |
| V29 |
Suitable for both wall and 35 mm rail mounting, spring clamp terminals instead of faston terminals |
| V94 |
Relay socket |
V93 or |
yes |
Suitable for both wall and 35 mm rail mounting, screw terminals instead of faston terminals |
March 1, 2014 |
| V99 |
Suitable for both wall and 35 mm rail mounting, spring clamp terminals instead of faston terminals |
| V95 |
Relay socket |
V93 or |
yes |
Suitable for both wall and 35 mm rail mounting, screw terminals instead of faston terminals |
March 1, 2014 |
| V99 |